4000 Lph Industrial RO System

4000 Lph Industrial RO System

RO Capacity 4000 LPH
Capacity(LPH) 1000 LPH
Usage/Application Industries
Automation Grade Semi-Automatic
Material Carbon Steel
Media Activated Carbon + sand
Water Source River Water
Purification Method Reverse Osmosis


 Pressure Sand Filter:18 X 65 vessel Containing Gravel & Sand (pentair ).
Material of Make : FRP/ Equivalent
Test Pressure : 12 Kg/ cm2
Opening : Top
Valve Specification
Make : Initiative
Type : Multi port Valve side mounting
Size : 1.5
Media : Pebble, Silex, Sand.
Strainer : 100 Micron
Purpose: Water stream from sand filter is passed through activated carbon filter bed which ensure
odor and colorless clear filtrate is also from chlorine.
II. Activate Carbon Filter: 18 X 65 Vessel Containing Gravel & Carbon.
Pentair make.
Material of Make : FRP/ Equivalent
Test Pressure : 10 Kg/ cm2
Opening : Top

Yes I am Interested

Valve Specification
Make : Initiative
Type : Multi port Valve side mounting
Size : 1
Strainer : 100 Micron
Media : Activated Carbon, : 1.5 Multi Port valve ( Nylon ).
III. Dosing Pump  Purpose : To remove the effect of Calcium and Magnesium responsible in the water
Dosing pump : 2 No
Make : E-Dose, Seko/Injecta Italy/Ultimate.
IV. Pre Filter: 20 X 20  Micron PP Filter USA 4 pcs (Big Blue).
Micron Filter stage 1
Purpose : After anti Scaling system water passes through micron filter stage 1having
filter cartridge of 20 micron porosity so as to produce clear water up to 20micron level.
Make : PP
Qty : One No s
Type : 20
Micron Filter stage 2

Qty : One No s
Type : 20
BIG BLUE MAKE.
V. High pressure pump, CRI : 5 HP for 4000 LPH.
Purpose : To feed Ro Membrane more than the osmotic pressure, considering flux
rate
Flow and recovery.
Material of Construction : S/S (4KW) Max
Type : Vertical centrifugal Multistage
Make : Grand fos / Equivalent
Qty : One
Feed Pump 02 Hp. CRI MAKE
VI. Membrane: 40 X 80 (4pcs) CSM or Toray for 4000.
Purpose : To reduce TDS (Total Dissolved Solids) level up to 99% and hence bring
the value dissolved solids to minimal level.
Type : Thin Film Composite
Dia : 8
Length : 40
No. of Membrane : Four.
Make : CSM/ Hydronotics / Hi-tech.
VIII. Dosing pump
Pressure Meter: 4 Pcs.